R2GATE Surgical KIT

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Implant Carrier • To pick up the fixture from the ampule and insert it to the ossetomy. Then turn it to clock-wise direc- tion 2~3 times manualy. • When it gets fixation from the osteotomy, connect the handpiece adaptor and...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Tap Drill • The purpose of tab drills in the R2GATE universal kit system is insertion test. some of implant are required this procedure before final fixture insertion. choose the one-step under size of tab to protect from enlargement...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Cortical Bone Drill • 권장 drilling speed: 300~800 rpm[/vc_column_text][vc_single_image image="1527" img_size="full" qode_css_animation=""][/vc_column][/vc_row]...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Ratchet Wrench • Used to exert more force than the Handpiece. • No bearing system : No breakage and no corrosion problems. • Arrow laser marking indicates direction of force.[/vc_column_text][vc_single_image image="1523" img_size="full" qode_css_animation=""][/vc_column][/vc_row]...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Hand Driver (1.2 Hex) • Used for all Cover Screws, Abutment Screws, and Healing Abutments. • Available in 4 lengths for added convenience. • Hand Driver can be directly inserted into the Torque Wrench without using an adaptor. • Hex tip can...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Drill Extension • No more than 35Ncm torque : May distorted when excessive force is applied. • Extends drills & other handpiece instruments[/vc_column_text][vc_single_image image="1515" img_size="full" qode_css_animation=""][/vc_column][/vc_row]...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Carrier Extension • To extend the length of implant carrier.[/vc_column_text][vc_single_image image="1511" img_size="full" qode_css_animation=""][/vc_column][/vc_row]...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Carrier-Handpiece Adapter • Useful to use the handpiece for the implant placement following initial delivery of a fixture with a fixture carrier.[/vc_column_text][vc_single_image image="1507" img_size="full" qode_css_animation=""][/vc_column][/vc_row]...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Implant Carrier[AR] • The purpose of tab drills in the universal kit system is insertion test. some of implant are required this procedure before final fixture insertion. choose the one-step under size of tab to protect from enlarge- ment...

[vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Cortical Bone Drill[AR] • Recommended drilling speed : 300 ~ 800 RPM[/vc_column_text][vc_single_image image="1498" img_size="full" qode_css_animation=""][/vc_column][/vc_row][vc_row css_animation="" row_type="row" use_row_as_full_screen_section="no" type="full_width" angled_section="no" text_align="left" background_image_as_pattern="without_pattern"][vc_column][vc_column_text]Cortical Bone Drill[AO] • Recommended drilling speed : 300 ~ 800 RPM[/vc_column_text][vc_single_image image="1499" img_size="full" qode_css_animation=""][/vc_column][/vc_row]...